The same measurement layer under every kind of plant. What changes between them is the quantity read and the protocol it comes over.

Industrial energy efficiency

Measure what each department, line and energy vector actually consumes, continuously, and keep the data ready for whoever has to verify it.

Modbus RTU/TCPM-Bus / wM-BusOPC-UA +2

Photovoltaics and agrivoltaics

Every plant in one view, whatever the inverter brand, with the Performance Ratio computed on your data instead of inside a closed portal.

Modbus TCP/RTU (SunSpec)IEC 61850IEC 60870-5-104

Water networks

Flow, pressure and levels district by district, in a system that speaks the remote-control protocols water operators already use.

ModbusIEC 60870-5-104DNP3 +1

Wastewater treatment

Process parameters and energy on the same time axis, so discharge compliance and cost per cubic metre can be read together.

ModbusIEC 60870-5-104PROFINET +1

District heating

Substations already come fitted for M-Bus remote reading. NeMo reads all of them and shows where the network loses heat and where the temperature drop does not add up.

M-Bus / wM-BusModbus

Storage and BESS

State of charge, health and cycles read from the BMS alongside the power exchanged, so you know what the battery is actually worth after two years.

Modbus TCP (SunSpec)CAN / CANopen (BMS)IEC 61850

Electrical substations

Currents, voltages and switchgear state read continuously, so a voltage dip stops being a story and becomes a measurement with a timestamp.

IEC 61850 (MMS/GOOSE)IEC 60870-5-104DNP3 +1

Biogas and biomethane

Feedstock, process and yield on one history, so you can see which input is actually paying and which is not.

ModbusOPC-UAPROFIBUS / PROFINET

Cold chain

Continuous temperature recording, with alarms that arrive before the load is lost and a history that stands up to an inspection.

Modbus RTUMQTT

Compressed air

Compressed air is the consumption nobody sees, because it has no meter. Give it one.

ModbusOPC-UAPROFINET

Data centres

PUE is by definition a ratio between two continuous measurements. If one of them is an estimate, it is not a PUE.

SNMP (PDU, UPS)ModbusRedfish / IPMI +1

Energy communities

NeMo sits under the community manager, not in its place: it brings the quarter-hourly readings from every meter point, so the split rests on data instead of estimates.

DLMS/COSEM via Chain 2Modbus (tramite gateway Chain2)

Production processes

Output, downtime and consumption on one timeline, so you can see what a part really costs and which stage is holding up the rest.

OPC-UAPROFINET / PROFIBUSModbus TCP/RTU +2

Heating and cooling

How much energy it takes to keep spaces comfortable, building by building, and how much of it you are spending to compensate for a badly tuned plant.

BACnet IP/MSTPModbusKNX +1

Fleet monitoring

Position, engine hours and fuel for every vehicle, read off the onboard bus, so maintenance follows real use rather than the calendar.

CAN / FMSOBD-IIMQTT +1

Installed base

Firmware version, state and diagnostics for every device you installed at a customer site, without asking whoever works next to it.

MQTTModbus TCP/RTUSNMP +1

Your plant is not
on this list?

The measurement layer is the same one. What changes is the quantity being read and the protocol it arrives on — tell us about your case.